Questions & Answers for: weak flame signal

Question about Heating & Cooling

1 Answer

...weak flame sensing device. As main burner ignitin occurs this creates a roll out condition , when this condition occurs it derives oxygen from the pilot light thus reducing flame signal and causing ...

Ad

...flame sensor. If it is OK then the gas valve coils may have to be replaced. EVEN THOU THE GLOW PLUG IS GLOWING IT MAY STILL BE BAD OR JUST WEAK ENOUGH TO CAUSE THE DRYER NOT TO LIGHT. THE GLOW PLUG ...

Ad

Question about HEATER RLP30 30,000-BTU PORTABLE LP PROPANE FORCED AIR HEATER

1 Answer

...flame my not be touching thethermocouple sufficiently and the thermocouple thinks something is wrong and stops the gas. Or the thermocouple can be weak and not give a strong signal to allow the gas ...

Question about HEATER RLP30 30,000-BTU PORTABLE LP PROPANE FORCED AIR HEATER

1 Answer

...that opens the gas valve, you don't want that signal to be too weak. It would be wise to clean the pilot supply, to have a cleaner flame. pressurized air does well with out having to remove

Question about Neptune MDG9700A Gas Dryer

1 Answer

...flame is uneven and weak right where the flame sensor is located, it will be treated as a failed ignition). In the worst case, the gas valve is defective and unable to detect the flame signal. ...

Question about NH150-DV-NG Indoor Direct Vent Natural Gas Tankless Hydronic Boiler NH-1501-DV

1 Answer

...flame rod is sending a weak signal to the control unit. Check for a loose flame rod electrical connector. Peek in the flame inspection windows to ensure there is a proper flame on that side of the ...

Question about 6 Gallon Water Heater SW6D S/D -

1 Answer

...ground terminal, there may be a flame sensor too, in this case clean it with 0000 steel wool it is just a ground rod and does not wear out but will build a film that can disrupt the weak DC

Question about 6 Gallon Water Heater SW6D S/D -

1 Answer

...flame seems weak. Its a natural gas system. you can remove the pilot assembly and blow air thru it and then run a small piece of wire thru it At the same time wipe the thermocouple end that you took ...

Question about SW4P Pilot Water Heater 3 Gallon Trailer Camper RV

1 Answer

...ground terminal, there may be a flame sensor too, in this case clean it with 0000 steel wool it is just a ground rod and does not wear out but will build a film that can disrupt the weak DC

Question about SW4P Pilot Water Heater 3 Gallon Trailer Camper RV

1 Answer

...flame of the pilot light and crates a weak electrical signal that operates the gas controls and has a limited lifespan. Turn off the gas and then simply remove the brass tube that sits in the pilot ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating & Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...