Question about Fan Company 5/1/1 Programmable Thermostat
White-Rodgers 1F58-58 to Hunter 44660 Old White-Rodgers has 8 wires and Hunter 44660 only has seven wire White-Rodgers uses: G,R,L,E,B,W2,Y,O Hunter uses: G,W\B,Y\O,RC,RC1,RH,Y1 Please help This is ...
Question about Fan Company 5/1/1 Programmable Thermostat
...White-Rodgers 1F56-444 to a Hunter 44155c digital. The old White-Rodgers had wiring of green / RC (jumper to RH) / yellow/ white/ and brown.... Now the white and brown were BOTH connected to the W ...
Question about Fan Company 5/1/1 Programmable Thermostat
white-rodgers.com/wrdhom/pdfs/instruction_sheets/0037-5421.pdf Here's a link to an article I wrote about how to control a 3-wire zone valve with a 2-wire thermostat. http://www.geekwisdom.com/dyn/node
Question about White-Rodgers 1F85RF-275 Thermostat and Wireless Remote Sensor Kit
wiring manual for a White Rodger thermostat model 1F58W-77. Trying to change it to a digital thermostat. we need the wiring diagram for the old White Rodger. Thank you! Please call the hometechline at
Question about White-Rodgers 1F85RF-275 Thermostat and Wireless Remote Sensor Kit
...White-rodgers F178 unit I purchased only appears to use 4 wires so I'm a litttle confused what to do with the common wire from the other side of each relay. may be able to jumper them as the are the ...
Question about White-Rodgers 1F85RF-275 Thermostat and Wireless Remote Sensor Kit
white rodgers having trouble getting wires right Hi. This is Aaron Moratalla from White Rodgers. See this link for the copy of manual. http://www.emersonclimate.com/Documents/White-Rodgers/instruction
Question about White-Rodgers 1F85RF-275 Thermostat and Wireless Remote Sensor Kit
white rodgers 1F82-51 Hi. This is Aaron Moratalla from White Rodgers. If you are looking for the wiring diagram of 1F82-51 see it in page 3 of the manual using link below:http://www.emersonclimate.com
Question about WHITE RODGERS 6 TERMINAL SOLENOID RELAY 12 VOLT 124-910
Wiring diagram for white Rodgers golf cart solenoid 4 terminal 36 volt What are the jumper wires there one for the big connections and one for the small Look like a fuse
Question about WHITE RODGERS 6 TERMINAL SOLENOID RELAY 12 VOLT 124-910
...White Rodgers 50A56-956. Getting the same result as the old board: clicks on, shuts off White Rodgers relay clicks shuts off Surveillance Cameras ... www.fixya.com > ... > Tags > relay clicks shuts ...
Question about WHITE RODGERS 6 TERMINAL SOLENOID RELAY 12 VOLT 124-910
White Rodgers 1F78 non-programable thermostat. The White-Rogers 1F78 thermostat is a single stage 5/2 day programmable thermostat. Home Depot has the manuals for one model of this thermostat, 1F78-151