Cardiozone Exercise & Fitness - Page 6 - Popular Questions, Answers, Tips & Manuals
Calibrate incline on Tjojan tr500 treadmill
Method 1: Press Stop and Speed Up, Insert the Key
To calibrate the incline, press and hold the stop and speed increase buttons. While holding the buttons, insert the safety key. The machine will now be in calibration mode. Press the Stop button once. Then, press one of the incline buttons to begin the calibration. It is recommended that you do not stand on the machine while the calibration is taking place.
The machine will move to its highest incline position, then to its lowest decline position. Please wait for the machine to come to a complete stop. When the machine stops moving, the calibration is complete. Remove the safety key from the console to exit calibration mode.
Method 2: Press the Stop Button, Insert the Key
To calibrate the incline, press and hold the stop button. While holding the button, insert the safety key into the console. The machine will now be in calibration mode. Press the stop button once. Then, press either the incline up or incline down button to begin the calibration. It is recommended that you do not stand on the machine while the calibration is taking place.
The machine will move to its highest incline position, then to its lowest decline position. Please wait for the machine to come to a complete stop. When the machine stops moving, the calibration is complete. Remove the safety key from the console to exit calibration mode.
4/6/2023 8:58:17 AM •
Exercise &...
•
156 views • 0 helpful votes
Urevo treadmill - knocking noise
A knocking noise coming from the rear roller of a Urevo treadmill can be caused by several issues. The following are some troubleshooting steps you can try:
- Check for loose bolts: Make sure that all bolts and screws that hold the frame and the roller in place are tight and secure.
- Check the belt tension: Ensure that the belt is tight enough. If the belt is too loose, it can cause knocking and other noise issues.
- Check the rollers: Make sure the rollers are not worn or damaged, as they support the weight of the belt and can affect the alignment of the belt.
- Check the deck: Make sure the deck is not damaged or worn, as this can cause noise issues as well.
If the noise persists after trying these steps, it's best to stop using the machine and seek assistance from the manufacturer or a professional repair technician. Using a machine that is making a knocking noise could potentially be dangerous and lead to further damage.
2/2/2023 2:11:16 PM •
Exercise &...
•
754 views • 0 helpful votes
Is an E8 error on Ancheer treadmill fixable?
Whether an E8 error on an Ancheer treadmill can be fixed depends on its underlying cause. Possible causes like a broken control board, loose wires, or a damaged motor can sometimes be resolved with proper repair or component replacement. It's best to seek assistance from the manufacturer or a professional repair technician for proper diagnosis and resolution.
1/29/2023 6:43:47 PM •
Exercise &...
•
587 views • 0 helpful votes
How do you fit a carbon bush to a Stannah 420 stair lift
Installing a carbon bush on a Stannah 420 stair lift requires some technical knowledge and experience, as it involves working with electrical components. If you are not familiar with stair lift maintenance and repair, it's best to contact a professional technician or Stannah service representative to ensure the proper installation and safety of the carbon bush.
However, if you have the necessary skills and knowledge, follow these general steps to fit a carbon brush to a Stannah 420 stair lift:
- Safety First: Before starting any work, ensure the stair lift is turned off, and the power supply is disconnected to avoid any electrical accidents.
- Access the Motor Compartment: Open the motor compartment of the Stannah 420 stair lift. This is usually located under the seat or at the base of the unit. You may need to remove some screws or panels to access the motor area.
- Locate the Carbon Brushes: The carbon brushes are small, rectangular-shaped components made of carbon and graphite, and they make contact with the motor's armature. Look for the existing carbon brushes, which might have worn down or need replacement.
- Remove the Old Brushes: Carefully detach the old carbon brushes from their holders. This may require gently pulling them out or undoing some clips or screws that secure them in place. Take note of how the old brushes were positioned so you can properly install the new ones.
- Install the New Carbon Brushes: Insert the new carbon brushes into their respective holders and secure them in place as per the manufacturer's instructions. Make sure they are positioned correctly and have good contact with the motor armature.
- Reassemble: Once the new carbon brushes are in place, reassemble the motor compartment by putting back any removed panels or covers and tightening any screws that were undone.
- Test the Stair Lift: Reconnect the power supply and turn on the stair lift. Test the unit to ensure the new carbon brushes are working correctly and that the stair lift operates smoothly.
- Regular Maintenance: Carbon brushes wear down over time, so it's essential to perform regular maintenance and inspections to identify when they need replacement. The frequency of replacement depends on the stair lift's usage and other factors.
Again, if you're unsure about any part of this process or lack experience with stairlift maintenance, it's best to seek professional help to ensure the job is done safely and correctly.
3/7/2023 5:07:57 PM •
Exercise &...
•
108 views • 0 helpful votes
Hello! , having problems with my treadmill. When the key is inserted, all lights go on and the incline works fine, but when you press start to start walking, the belt does not move and display E2.
Error code E2 on a treadmill typically indicates a problem with the speed sensor. The speed sensor is a small device that measures the speed of the treadmill belt and sends a signal to the treadmill's control panel. If the sensor is not functioning properly, it can cause the treadmill to display an E2 error and prevent the belt from moving.
There are a few potential causes of an E2 error on a treadmill:
- The speed sensor may be loose or misaligned. Make sure that the sensor is securely attached to the treadmill frame and properly aligned with the magnet on the flywheel.
- The speed sensor wire may be damaged. Check the wire for any visible damage, such as fraying or cuts.
- The control panel may be malfunctioning. If the error persists even after checking the sensor and wire, the control panel itself may be the issue. In this case, it may be necessary to have the treadmill serviced by a professional.
I hope this information is helpful. If you continue to experience problems with your treadmill, it is recommended to have it serviced by a professional to ensure that it is functioning safely and correctly.
12/19/2022 9:34:04 AM •
Exercise &...
•
848 views • 0 helpful votes
My treadmill run for a few second and stops
There could be several reasons why your treadmill is stopping after running for only a few seconds. Here are a few things you can check:
- Power source: Make sure your treadmill is properly plugged in and that the power outlet is working.
- Safety key: Ensure that the safety key is in place and fully inserted into the console. If the safety key is not properly inserted, the treadmill will not function.
- Motor: If the motor is not working properly, the treadmill may stop after running for only a few seconds. Check the motor by turning the treadmill on and listening for any unusual noises.
- Belt: A loose or worn-out belt can cause the treadmill to stop running. Check the belt tension and replace the belt if necessary.
- Control board: If the control board is malfunctioning, it can cause the treadmill to stop running. Check the control board for any signs of damage or wear.
If you are unable to diagnose the issue, it may be best to contact a professional to come and take a look at your treadmill.