John Deere Garden - Page 9 - Recent Questions, Troubleshooting & Support
My John Deere 997 keeps giving me the starter thermal protect mode can't figure out what's wrong
There's little in free information available regarding 997 DTC errors other than the handful in the owners manual.The only two temperature sensors I find in the wiring diagram are engine and transmission and only the transmission temperature interrupts the PTO so I believe the "start thermal protection" is a hydrostat pump overheat state and shutting down the PTO is their way to protect the pump.My only suggestion is make sure the hydro pump is clean and clear of debris and service the hydro, new filter and replace fluid.
John Deere 2250 Tractor, nothing works!
Check battery voltage.
It's an older mechanical injector diesel and fuel control so once running it needs no electrical power. The dash lights etc. are easily powered by the alternator. But once you shut if off, a bad battery cell or poor battery connection may effective kill the electrical system.
John Deere six 46 son hit rock and blades cut for about 2 min then stopped and won't come back on mower runs fine
With the mower turned OFF check the blades to see if they aren't bent and if it spins freely. There should be resistance when you hand turn the blades. A bent blade can jam and lock up the drive system. If the blade spins freely and has no resistance check the drive belts from the blade pulley to the gears that run the blades. Hopefully you have just had a drive belt come loose or break, a reasonably cheap and easy fix. If the belts are OK you will need a mower mechanic to look at the gearing for the blades.
Why do i not get power to the pto of my john deere lx280?
Check the resistance of the PTO clutch winding with the PTO power cable disconnected. It should read 2 - 4 ohms.
The engine does not need to be running for PTO to engage but all safeties must be operational.
I believe the red led ON indicates the PTO clutch relay is (should be) energized. So if the red led is off then the PTO relay is not energized hence no power to the clutch. Check all fuses. You need to test your way back from the PTO switch to the PTO relay, through the safeties.
Belt diagram LX288 John Deere 48
https://www.google.com/url?sa=i&url=https%3A%2F%2Fwww.mylawnmowerforum.com%2Fthreads%2Fjohn-deere-l-g-belt-routing-guide.2923%2F&psig=AOvVaw0awGaSGkh5EGkvGr-geX1F&ust=1645217027500000&source=images&cd=vfe&ved=0CAgQjRxqFwoTCOid15XNh_YCFQAAAAAdAAAAABAF
Not finding what you are looking for?