Kenmore Dehumidifiers - Page 5 - Recent Questions, Troubleshooting & Support
Compressor not working
ck your setting on control panel sometimes they get changed , also ck that your catch bucket is fully installed sensors are there that keep it from running if it does not have a bucket installed
I don't understand the timer on a Kenmore Dehumidifier
I do believe this one of those models that uses one display for both setting of humidity level and the timer , make sure you are viewing the timer function and not the humidity function , this is a very common complaint with these type as many times one sets the on time correct but then sets what they believe to be off time when they really are adjusting the humidity room level , there should be tiny lights that show function you are adjusting
Unit only runs when set to 1 cnt
unit runs If set to continuous mode only ? the other settings are a time off function that lets unit run only a portion of day , saves energy
Why is it rattling now , and how can i fix it?
noisey machines is a very common complaint I hear , most times it comes from being placed on a non level floor , and only two or three of the four legs are touching the floor , this makes it go off balance , second on units that run for greater than a year , they pick up build up on there fans and this makes it Micro wobble , fans can be removed and cleaned and legs can be shimmed to touch floor
My humidifier blowes hot air
if it's working well it should , unit should be removing all the moisture from air expelling out back , so its dry air
its when coils freeze up then you have a indication of problems
Freezes up
most units draw in the front and expel from the rear air , keeping filters clean (never run without one) is important for this function , frost on coils is a sure sign that air flow is low , or might be unit has lost [part of its gas charge due to heat build up from loss of cooling
How can you tell if the compressor in the dehumidifier is working?
listen for it , compressors have a distinct sound of tiny rocks hitting a pan (that not what's really going on in there ) that fans don't have
most units have a timer function that makes u wait for compressor to come on long after fan starts , so u might have to listen for up to fifteen minutes for it
How do I fix leaking dehumidifier?
units that leak some times are a total loss but not allways , sometimes its just not being used on level surface (water seeks level allways) , there are lots of ports inside that need to be kept clean for all the units water to drain out , look inside with a flashlight to see if any buildup is obvious that might be cleaned off ? if not a last effort is to remove cover to see 1st hand what cause is(remove power plug 1st) , rust /mold/dust are all common things to find inside that affect units operation
Model40752301
ck to see that bucket is installed all the way back inside cabinet , they sometimes hook the bucket presents switch together with the full switch
6/6/2015 2:04:02 AM •
Kenmore...
•
Answered
on Jun 06, 2015
How does a humidifier pump stop
if your talking about a humidifier that's connected to a hvac system , there are two basic types , one uses a wheel similar to one a small pet rodent would exercise its self on , but this one is covered with a mesh that holds water, and a motor not a rodent turns it , fresh water is maintained in a dish in bottom of unit by a level activated valve ,it's activated in two methods one by airflow switch (paddle) and another by being connected to blower motor of air handler(electrically)
the other type is nozzle type , these need to be mounted in long straight runs of main duct work not more than ten feet from furnace (heat) these simply have a air flow switch that opens a valve to let house water into nozzle in duct , much smaller than 1st version unit
6/6/2015 2:02:46 AM •
Kenmore...
•
Answered
on Jun 06, 2015
The full bucket light stays on yet no water is collected
if water full light stays on the compressor wont start and remove water from air , investigate why light stays on ? is bucket really full? is sensor knocked out of its fragile holder ? is bucket all the way inside machine so that sensor is connected ?
How to repair my kenmore 58054501500
ck the water catch bucket , sometimes ive seen machines stop after running a few minutes because it shook catch bucket from its perch
6/6/2015 1:47:59 AM •
Kenmore...
•
Answered
on Jun 06, 2015
Manage my life com sears
if frost is building up on coil face with it running 24 hrs or more , then id say yes it's low on a gas charge
6/6/2015 1:45:24 AM •
Kenmore...
•
Answered
on Jun 06, 2015
Not finding what you are looking for?