Kyocera FS1118, error code C6400, how do I resolve
Hi
Error C6400 appears in Kyocera FS118 when Zero crossing signal problem occurs i.e when the engine PWB doesnt detect the zero crossing signal. This can occur due to --
#1 Poor contact in the connector terminals.
#2 Defective power supply PWB.
#3 Defective engine PWB.
To reset it from Mainatince mode turn the power switch off and open the front cover. Now, turn the power switch on and press the system menu/counter key to enter the maintenance mode.
1. Press the enter key. A selection item appears.
2. Select Execute using the up/down cursor keys.
3. Press the enter key. The fusing problem data is initialized. (Four service calls, namely C6000, C6020,
C6050, and C6400 are reset.)
4. After this is complete press the back key. The indication for selecting a maintenance item No. appears.
Daniel Scott
Kyocera FS 4000 cassette error
under the front of the cassette on the bottom is a white catch if you pull it towards you the paper will spring up. more then likely it is not automatically getting pushed when you put the cassette in.
if this is not correct if you take the cassette out and look in where you took it out of there should be a arm hanging down just left of center that is the paper out sensor arm of that is broken it could be your problem also
9/21/2017 1:21:21 PM •
Kyocera...
•
Answered
on Sep 21, 2017
Kyocera laser printer toner refill
refill...uh oh probably wouldnt try it..there's is like only 1 company that does kyocera refill toners.....call KATUN... you can try to find that on the internet..you most likely willl have to buy actuall kyocera toner..
7/21/2017 7:49:50 AM •
Kyocera...
•
Answered
on Jul 21, 2017
Call service 6000:0098269
6000 Broken fuser heater lamp wire
The temperature does not reach 100°C/
212°F after the fuser heater lamp has
been turned on continuously for 30 s.
30/31 ppm printer (EUR/USA model):
The temperature does not rise by 1°C/
1.8°F after the fuser heater lamp has
been turned on continuously for 5 s during
printing.
35/37 and 45/47 ppm printers (EUR/USA
model):
Fuser thermistor M detection
temperature does not rise by 1°C/1.8°F
after the fuser heater lamp has been
turned on continuously for 10 s during
warm-up or at standby.
Fuser thermistor S detection
temperature does not rise by 1°C/1.8°F
after the fuser heater lamp has been
turned on continuously for 5 s during
warm-up or at standby.
The temperature does not rise by 1°C/
1.8°F after the fuser heater lamp has
been turned on continuously for 5 s during
printing.
Poor contact in the
fuser thermistor M
connector terminals.
Reinsert the connector (See page P.1-5-19).
Fuser thermistor M
installed incorrectly.
Check and reinstall if necessary (See page
P.1-5-19).
Thermal cutout
triggered.
Check for continuity. If none, replace the
thermal cutout (See page P.1-5-19).
Fuser heater lamp
installed incorrectly.
Check and reinstall if necessary (See page
P.1-5-19).
Broken fuser
heater lamp wire.
Check for continuity. If none, replace the
fuser heater lamp (See page P.1-5-15).
1/23/2017 8:10:17 AM •
Kyocera...
•
Answered
on Jan 23, 2017
Red light in the first
The problem you are facing is a hardware issue try power cycling the printer by taking out the power cable and wait for 3 minutes and try to turn it back on if the issue still persists contact the manufacturer.
Not finding what you are looking for?