Manitowoc Refrigerators - Recent Questions, Troubleshooting & Support

0helpful
1answer

Manitowoc ice maker, model QY0424A. It is running but not harvesting ice. Uses 404a refrigerant. Also, water reservoir over fills. red light keep blinking. Refrigerant is ok. what is the problem ?

Over filling may be the cause of the problem, water solenoid valve not working, bad float switch, bad timer. If all other sequence check out ok, then I would be looking at the water valve power and capability to shut water off.
9/19/2020 8:53:56 PM • Manitowoc... • Answered on Sep 19, 2020
0helpful
1answer

Manitowoc qy Split Ice Machine80º ambient

TXV?
2/16/2018 2:38:18 AM • Manitowoc... • Answered on Feb 16, 2018
0helpful
1answer

MANITOWOC 453 MAKES BEAUTIFUL ICE, NO PROBLEM, HOWEVER WATER IS POURING OUT THE BACK FROM WHAT I BELIEVE IS THE COMPRESSOR COOLING LINE

Most likely that is a drain line and should be routed outside v
11/13/2017 11:13:54 PM • Manitowoc... • Answered on Nov 13, 2017
0helpful
1answer

Have a Manitowoc SY0324A ice/water machine. continuous water drip from water dispenser.

The seals are defective, either replace the valve or rebuild it with new seals.
10/28/2016 11:04:59 PM • Manitowoc... • Answered on Oct 28, 2016
0helpful
1answer

Manitowoc QD0132a ice machine makes

8/2/2015 9:39:14 PM • Manitowoc... • Answered on Aug 02, 2015
0helpful
1answer

Manual for manitowoc ice maker. model #: B570 and serial # : 050120331

Would suggest you contact the factory or search on-line. A B570 is only an insulated storage bin. The door hinges are the only moving parts.
3/7/2015 5:31:46 PM • Manitowoc... • Answered on Mar 07, 2015
0helpful
1answer

My QD0172A is not making full ice cubes. This

Most common issue for this is an improperly adjusted thickness probe. Locate the screw at the top of the probe and turn it clockwise about 1/2 turn. Wait for the next harvest to determine if it needs more adjustment.
3/7/2015 5:29:45 PM • Manitowoc... • Answered on Mar 07, 2015
0helpful
1answer

My Manitowoc series 250 only makes 1/2 sheet of ice(bottom half) how can i get it to make a ful sheet again??? i've played with the thickness but the bottom coils build up faster than the top ones..

There are a few possibilities. First, water could be leaking out of the sump. You don't note the actual model, so this could be due to a scaled-up dump valve, or a poorly set float valve, depending on the model and age of machine. Check the outlet of the drain line as it's producing. If water is being drained out during production, locate the source and deal with it. If it's being fed hot water, this will occur, as well. Beyond this, you'll need a tech to determine the reason. Most common would be starving txv or improper refrigerant charge.
3/7/2015 5:27:03 PM • Manitowoc... • Answered on Mar 07, 2015
0answers
0answers
Not finding what you are looking for?
Manitowoc Logo

60 questions posted

Ask a Question

Usually answered in minutes!

Top Manitowoc Refrigerators Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Are you a Manitowoc Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...