Labels sticking to ribbon
If I had a guess...this label material sounds old or stored improperly...possibly to much head pressure....I would suggest some known good material and retry.
11/24/2021 6:23:43 PM •
Zebra Z4M...
•
Answered
on Nov 24, 2021
Label Printing stuck in queues
I think your problem comes from your spool server. Check if you can select not to reprint on errors. As far as the error issue is concerned, i need to konw the reason of the errors to help
11/11/2021 10:27:52 PM •
Zebra Z4M...
•
Answered
on Nov 11, 2021
Unable to reset the printer, even to reset the password
after you reset to default settings you need to save changes for it to take effect. there is also another password. 1234 will only take you to level 2 you need the level 3 password. this password can be found in the service manuals and some of the full manuals
Error conditon ribbon out
if you are not using a ribbon you should configure your printer properties in direct thermal the same with your printer configuration in LCD Panel, if your printer properties is different with the LCD Panel error condition ribbon out will come out to your LCD Panel
There is error "bblock"
BBlock is BOOT Block. The printer is not booting up the settings completely. Probably got corrupted. You will need to download the bootblock version for this printer & upload it via either USB or LPT1 port. You should contact Zebra so they can direct you to the proper Zebra site for the download & instructions. The process of the upload is no more that 15-20 minutes.
Zebra phone # is 847-913-2259 I think option 2 is tech support. be sure to have s# of printer & tell them you need to find the boot block & installation info for the S4M. Good luck.
I am having problems with Zebra printer MDL#ZM400
Try entering the Menu system and exiting, whilst exiting and instead of saving permanent, cycle around to load defaults. once you have done that make sure the settings are as you need such as Thermal Transfer etc and save permanent. You won't have a problem after that. If you do I would be checking the page setup in the software to make sure it fits the lables.
Printing error condition
First clean the sensor tag and sensor head open and tape. Then perform a calibration label pressing the PAUSE and FEED buttons and turn on the printer, release the keys until it starts to move the label. Wait until you are finished and ready to print.
How do you set a static IP address on the Zebra
If this is a wireless printer then all you need to do is set an address reservation on your router and then set up a fixed IP port on your printer driver.
First: Install the printer driver as a normal USB printer by connecting the cable during the install process dont use the wizard if you can help it.
Second : Find your MAC address for the printer (all types of Network Cards MUST have one) this will either be in the LCD control panel or on the bottom of the printer on a label and set this in your admin panel of your router to say 192.168.0.10 for example. You can normally enter this using 192.168.0.1 but all routers are different. Check here for your make and model
http://www.routerpasswords.com/Last : Goto the printer driver properties for the USB printer you have just install click the port tab and click add standard IP port as shown below, then disconnect the USB lead this is only required to make sure the correct inf file is used on the driver install.
Thats is. !!!